With port sizes up to ¾”, the new flow switches are aimed at monitoring fluid systems with higher flow rates. This inline flow switch also accommodates fluid pressures to 1,000 psi. Twenty-five percent larger than its FS-380 sibling, it is ideal for processes that push more fluid through their systems and demand lower pressure drop. Larger semiconductor equipment demands greater coolant and the coolant fluids are denser than traditional DI water. This combination has forced system designers to reduce pressure drop to curtail increasing pump sizes. Unit has set point accuracy to ±20 percent maximum, and operates in temperatures ranging from -20 to 250 degrees F. FS-480. For more information, contact Gems Sensors Inc., at 800-378-1600 or go to www.gemssensors.com